1083-Plasma Station %ld Cut Gas Pressure

Print Print

Message

Cause of Error

Correction

(1083)

Plasma Station <N> Cut gas pressure

will be found only when using Smart Flow 1 & 2, with PT15, PT19 or PT600 torch.

This error is generated if the Cut Gas Pressure switch input is in the wrong state. This pressure switch is actuated by start gas during the start gas sequence, then by cut gas during cutting.

The CNC watches this input for a change of state, from the off condition to the on condition when one of the gas solenoid valves is energized. An error is generated if the input is on when it should be off, or if the input is off when it should be on.

If this error message appears, check the following:

1. Check the Nitrogen and Oxygen supply

pressures at the regulator panel. They should

be adjusted to deliver 120 PSI to the plumbing

box.

2. Check the appropriate EPEP at the Vision CNC.

It should turn on and off with the gas flow.