Visit http://www.esabna.com/ for more information about our products.

182-Power supply interrupted at station

Print Print

Message

Cause of Error

Correction

(182)

Power supply interrupted at station <n>

Only for machines with ATHC and MB01 stations.

The ATHC stations report improper states to the control system. If the power supply is interrupted at a station, this error message is displayed:

- if the power supply is interrupted at an active (selected) station

- if you try to select the station via the keyboard or the main program

- with every MIP initialization. A MIP initialization takes place every time the voltage is switched on.

Inform ESAB service.

Check Led's on the ATHC Card and MB01.

-If Green Light is off
  -check power supply
  -check input power to card

-If Yellow light is On, download station constants

- If Yellow light is Blinking or off
  -check communication cable
  -remove all cards from main board
  -swap main boards